ZDMVP
DESCRIPTION OF FUNCTION, SECTION
24
They comprise a
• housing (1) and a
• cartridge (2).
Pressure in the branch circuit is manually set by adjust-
ment mechanism (3).
Pressure reducing valves are normally open, permitting
fluid to flow from port P1 to P2. Pressure at port P2 is
applied on main spool (5), and via orifice (4), on the
spring-loaded side of main spool (5). If pressure at port
P2 exceeds the value set at spring (6), pilot poppet (7)
opens.
Fluid flows from the spring-loaded side of main spool (5)
through orifice (8) and pilot poppet (7) to spring
chamber (9) into tank. Main spool (5) modulates to
maintain pressure at port P2 constant.
Pressure reducing valves type ZDMVP06 are pilot
operated pressure reducing valves in sandwich plate
design. They r
educe pressure in a branch circuit lower
than that of the main circuit.
MODULAR VALVES
PRESSURE REDUCING
VALVES, PILOT OPERATED